Firmware & Manual - Latest

A full detailed list of changes can be found at the end of each manual. Please Contact Us for technical questions and clarification about our Toptech Systems hardware products.

Latest SMP Software
Latest ML Software
Latest SCS Software
Standard Firmware Manual

New Features / Changes:

  • No new features added.

Bug Fixes:

  • Manual control of simulated of discrete inputs over port 7.
  • ML automated reports (monthly reports) occur every 60 seconds when NTP was enabled. Time zone offset was being miscalculated.
  • ML automated reports (monthly reports) occur every 60 seconds when time zone not set to zero. Time functions were not properly dealing with UTC to localtime conversion when NTP was enabled.
  • Alibi Log (PTB) printers only use 7 data bits but can print several international UTF8 characters that need to be converted into <128 ascii characters (DIN 66003). Specifically, ‘Ä’ => ‘[‘, ‘Ö’ => ‘\’, ‘Ü’ => ‘]’, ‘ä’ => ‘{‘, ‘ö’ => ‘|’, ‘ü’ => ‘}’ and ‘ß’ => ‘~’.
  • Adjust Alibi Log (PTB) trace messages so they do not flood the message log when enabled.
  • When Final Trip Volume is misconfigured to a large value and product flow continues to flow past the Final Trip State, it was possible for the meter and preset totalizer to differ by a few gallons.
    • Update the Final Trip Max Time parameter to raise a *FINAL TRIP Alarm if the Flow Rate does not drop to zero within this time when the Final Trip state is entered.
    • The Final Trip Max Time will no longer cause Final Trip state to end if flow is still occurring. Flow MUST stop to leave this state. This will prevent ending a batch/transaction, starting the next component in a blend or clearing a meter total until all flow has stopped.
  • If a meter clear occurred when flow was occurring, it was possible for component meter and batch totals to differ by a fraction of one gallon. Calculations are now identical for these two totals.
  • Component Status Screen some data fields may initially/briefly appear as ######.
  • For LACT applications using the Water Cut Calculations, Temperature value was corrupted if the meter total was cleared.
  • Network driver RX buffer memory misalignment causing random network loss.

Latest RCU Sofware

New Features / Changes:

  • No new features added.​

Bug Fixes:​

  • Network driver RX buffer memory misalignment causing random network loss.

Latest SCS SLATE Software
Latest ML SLATE Software
Latest SMP SLATE Software
Latest SLATE Firmware Manual

New Features / Changes:

  • No new features added.

Bug Fixes:

  • Manual control of simulated of discrete inputs over port 7.
  • ML automated reports (monthly reports) occur every 60 seconds when NTP was enabled. Time zone offset was being miscalculated.
  • ML automated reports (monthly reports) occur every 60 seconds when time zone not set to zero. Time functions were not properly dealing with UTC to localtime conversion when NTP was enabled.
  • Alibi Log (PTB) printers only use 7 data bits but can print several international UTF8 characters that need to be converted into <128 ascii characters (DIN 66003). Specifically, ‘Ä’ => ‘[‘, ‘Ö’ => ‘\’, ‘Ü’ => ‘]’, ‘ä’ => ‘{‘, ‘ö’ => ‘|’, ‘ü’ => ‘}’ and ‘ß’ => ‘~’.
  • Adjust AlibiLog (PTB) trace messages so they do not flood the message log when enabled
  • bol_header_index in LUA was not being properly calculated when ML started to delete the oldest transactions to make room for newer transactions and caused an “attempt to index a nul value” LUA error. Note: Referencing transactions over the Rest API directly with the Bol Number does not work. Instead first read the transaction at #1, then calculate the new index by (BOL Number + 9999 – BOL Number of #1) % 9999.
  • When Final Trip Volume is misconfigured to a large value and product flow continues to flow past the Final Trip State, it was possible for the meter and preset totalizer to differ by a few gallons.
    • Update the Final Trip Max Time parameter to raise a *FINAL TRIP Alarm if the Flow Rate does not drop to zero within this time when the Final Trip state is entered.
    • The Final Trip Max Time will no longer cause Final Trip state to end if flow is still occurring. Flow MUST stop to leave this state. This will prevent ending a batch/transaction, starting the next component in a blend or clearing a meter total until all flow has stopped.
  • If a meter clear occurred when flow was occurring, it was possible for component meter and batch totals to differ by a fraction of one gallon. Calculations are now identical for these two totals.
  • Component Status Screen some data fields may initially/briefly appear as ######.
  • For LACT applications using the Water Cut Calculations, Temperature value was corrupted if the meter total was cleared.
  • Network driver RX buffer memory misalignment causing random network loss.